SHALIMAR GROUP
NAME OF THE DEPARTMENT :
DOCUMENT CODE NO.
EXECUTION






NAME OF THE DOCUMENT :
PAGE NO.
TOTAL PAGES.
CHECKLIST FOR EXTERNAL PLASTER

0
1

0
1
CHECKLIST FOR EXTERNAL PLASTER

Sr. No:




SITE : SHALIMAR ANTHURIUM
LOCATION :
DATE :
Ref. Drawing No. ________________________________________
Sr. No.
Job Description
YES
NO
NA
1.
All concrete & masonry surface are in line & plumb



2.
Hacking of all R.C.C. surfaces



3.
All mortar to be mixed in mixer, material measured in boxes and water cement ratio maintained at 0.7



4.
The scaffolding self-standing and rigid window frames have been protected and wrapped with plastic sheets



5.
Thickness level marks have been made at a distance of 4 M c/c.  plaster thickness is not more than20 mm.



6.
The thickness marks to be make in two layers of 12 mm and 8 mm



7.
Masonary has been pre-wetted 24 hours in advance



8.
Metal is fixed in cm at the junction of masonary & RCC surface



9.
Keep 3, 4 day gap between 1st coat and 2nd coat for double coat plaster



10.
Finish scaffolding holes properly & immediately



11.
Vertically of window opening jams as well as horizontally of its bottom sill and top to be checked during plaster



12.
For parapet wall leave plaster for 40 cm for water proffing purpose.



13.
Clean the terrace above plaster work



14.
Cure the plaster for 15 days



15.
Plaster should be checked for its thickness line, level and plumb



                                                                                          

                                                                                          SIGN. OF SITE ENGINEER
CORRECTIVE ACTION PROPOSED



Sign of Project Manager                                                       Sign of Project Manager
      Contractor                                                                                  Shalimar Group