SHALIMAR GROUP | NAME OF THE DEPARTMENT : | DOCUMENT CODE NO. | |||||||||||||
EXECUTION | |||||||||||||||
NAME OF THE DOCUMENT : | PAGE NO. | TOTAL PAGES. | |||||||||||||
CHECKLIST FOR PLUMBING SHAFT (WATERPROOFING TOILET) | 0 | 1 | 0 | 1 | |||||||||||
CHECKLIST FOR PLUMBING SHAFT (WATERPROOFING TOILET) | |||||||||||||||
Sr. No: | |||||||||||||||
SITE : SHALIMAR ANTHURIUM | LOCATION : | DATE : | |||||||||||||
Ref. Drawing No. ________________________________________ | |||||||||||||||
Sr. No. | Job Description | YES | NO | NA | |||||||||||
a. | surface preparation | ||||||||||||||
1. | check sufficient cleaning (ghadai) | ||||||||||||||
2. | check leakage by ponding method | ||||||||||||||
3. | apply chat coat on rcc and make fillets (watta) at corners. | ||||||||||||||
b. | Basecoat | ||||||||||||||
1. | Base coat water proofing use 1:4 cement mortar with approved w/p compound. | ||||||||||||||
2. | Slope of 1:100 from entrance towards the water escape pipe. | ||||||||||||||
3. | Base coat height on walls is upto 1m above floor level. | ||||||||||||||
4. | ponding with water for 3days | ||||||||||||||
c. | Brickbat & final finishes. | ||||||||||||||
1. | check lvl of flooring is available. | ||||||||||||||
2. | Select the bricks bats and prewet the brick bat | ||||||||||||||
3. | Lay the brick bat | ||||||||||||||
4. | See that min width is achieved between the brick bat. | ||||||||||||||
5. | Joints filled with 1:4 mortar with approved w/p compound. | ||||||||||||||
6. | Slope is 1:100 from entrance to water escape. | ||||||||||||||
7. | Allow curing for min 3 days. | ||||||||||||||
8. | Final topping coat should be 15mm thick with (1:3) slope towards nahani trap | ||||||||||||||
9. | Roughen the top coat surface by wire brush. | ||||||||||||||
10. | Continues curing should be done for 7 days. | ||||||||||||||
SIGN. OF SITE ENGINEER | |||||||||||||||
CORRECTIVE ACTION PROPOSED | |||||||||||||||
Sign of Project Manager Sign of Project Manager Contractor Shalimar Group |