Inspection chamber General specifications





Size

45 cm x 60 cm (18” x 24”) or 45 cm x 90 cm (18” x 36”), depending upon the number of pipe connections entering the chamber, for two pipe connections use one chamber of 45 cm x 90 cm size inspection chamber.

Location

As per the drawing on the proposed alignment.

Wall thickness

23 cm (9”) of burnt bricks.

Inside plaster

Smooth finished with extra cement in C.M. 1:4.

External plaster

Sand faced plaster in C.M. 1:4.

Gully/channel

P.C.C. of grade M10. Finished smooth with cement.

Frame and Cover

Frame to be fixed in 10cm (4”) thick P.C.C. of grade M10, before internal and external plaster.

Precast concrete covers for the chamber in the parking should be designed for vehicular loading.

Bottom level

15 mm(1/2) below the incoming flow and flushed to the outgoing flow.

Top of chamber

Same as the parking floor level/road level.





Spacing of manholes/chambers (inspection chambers)


Dia. Of sewer line
Spacing on straight line
Dia. Up to 300 mm
Maximum 55 m
Dia. 301 to 500 mm
Maximum 75 m
Dia. 901 to 900 mm
Maximum 90 m
Dia. Beyond 900 mm
Maximum any interval as approved by authority