VERTICAL SECTION OF COLUMN

  • Clean the M.S. surface thoroughly by mechanical means like wirebrushing etc. to remove loose rust.

  • Apply ‘Rusticide’ solution by means of cottonwaste swab so as to wet the M.S. surface thoroughly in case of heavily scaled surface. Allow to dry for 24 hours. Avoid contact with water. Brush off any loose particle by means of a soft paint brush.

  • Prepare a slurry of ‘Polyalk Fixoprime’ and cement in 1:1 proportion and mix to a homogeneous consistency free from lumps. A low speed stirrer may be used for getting a uniform consistency. Apply this slurry by brush uniformly on the cleaned steel surface.

  • Apply another coat of this slurry within 2 hours of applying the first coat. In case of reinforcement steel, the second coat may be made of 1:1.25 instead of 1:1.

  • Allow to air cure for a minimum of 48 hours.